Industrial Ultrasonic Cleaners
Compare heated ultrasonic cleaners for parts and components
Explore industrial ultrasonic cleaners for compatible workshop parts, tools and mechanical components. Compare our 30L and 38L machines around the size of your workpieces, the contamination you need to remove and the controls your cleaning process requires.
Look beyond the litre rating: usable basket space, material compatibility and the cleaning liquid all affect suitability. For equipment supporting other cleaning tasks, browse our Cleaning Equipment collection.
CJ-100SD 30L Industrial Ultrasonic Cleaner – Heated, 40kHz
Choosing an ultrasonic parts cleaner
An ultrasonic cleaner treats immersed components using sound energy transmitted through a cleaning liquid. The process creates cavitation: small bubbles form and collapse, helping dislodge contamination from surfaces in contact with the liquid. This can assist cleaning around recesses and detailed shapes that are difficult to reach manually.
Choose the machine around the complete process. The part must fit, its materials must tolerate the treatment, and the liquid and operating settings must suit the contamination. A larger bath or higher setting does not automatically produce a better result.
Compare our 30L and 38L ultrasonic cleaners
| Model | Listed features | Selection checks |
|---|---|---|
| CJ-100SD 30L ultrasonic cleaner | 30L tank; listed 40kHz operation; integrated heating; digital controls; degas function and drainage. | Confirm usable basket dimensions, the supplied configuration and the settings needed for your components. |
| 38L industrial ultrasonic cleaner | 38L tank; listed 40kHz operation; 20–80°C heating range; adjustable timing and drainage. | Confirm component fit, basket clearance and any additional process features required for repeated batches. |
The nominal capacities differ by 8 litres, but this does not establish an equivalent increase in component size or batch throughput. Compare the usable cleaning space and supplied features before deciding.
Tank capacity, basket dimensions and batch loading
Measure the component in its cleaning position
Record length, width and height, including protruding fittings. Check the usable basket dimensions and working immersion depth rather than relying on the external machine size or nominal tank volume. Basket space is smaller than the surrounding tank.
For batches, plan how parts will sit without overcrowding or trapping air. Internal cavities need a loading arrangement that lets the liquid reach the surfaces requiring treatment. Ask about basket load limits if you intend to clean heavy components.
Use the specified basket or support
Use the support arrangement prescribed for the machine. Avoid placing components directly on the tank floor; a suitable basket keeps parts supported above it. Confirm whether the required basket is included before ordering.
Frequency, power and temperature
Both product listings identify 40kHz operation. Frequency describes the ultrasonic oscillation rate, while power and heating describe separate characteristics. Compare these specifications individually rather than treating them as interchangeable measures of cleaning performance.
When comparing wattages, establish whether each figure represents ultrasonic power, heater power or total input. Power per litre alone cannot account for loading, bath geometry, operating modes or the cleaning chemistry.
Heating can support a compatible cleaning process, but the appropriate temperature depends on the liquid, contamination and component. A machine's maximum temperature is an operating limit, not a recommended setting for every job.
Applications: automotive parts, tools and metal components
Carburettors and automotive components
For removable automotive parts, establish which materials and finishes are present and whether disassembly is required. Seals, coatings, adhesives and sensitive assemblies can change suitability. A cleaner large enough to hold an item is not automatically suitable for treating it.
Provide component dimensions and contamination details when comparing the 30L parts cleaner with the 38L ultrasonic cleaner.
Aluminium, brass and other metals
Do not choose a liquid solely because it is sold for metal cleaning. Confirm compatibility with the specific alloy, finish and contamination through the chemical supplier's guidance. Include the concentration, temperature and contact time in that check.
For tools, bearings and assembled components, also establish whether cleaning could remove necessary lubrication and what inspection, drying or re-lubrication steps are required afterwards.
Preparing and running an ultrasonic cleaning process
- Confirm compatibility: check the item, cleaning liquid and machine instructions before treatment.
- Prepare the bath: use the specified concentration and working fill level. Do not run the cleaner empty.
- Prepare fresh liquid for use: follow the machine's degassing instructions where required. The CJ-100SD listing includes a degas function.
- Load the basket: support components correctly and allow liquid access to the surfaces being cleaned.
- Select the process settings: use temperature and cycle guidance appropriate to the component and cleaning liquid.
- Inspect the result: complete any required rinsing, drying and subsequent care before returning the component to use.
What does degassing do?
Freshly prepared liquid contains gas that can affect ultrasonic action. Degassing helps prepare the bath by removing gas before cleaning. Use the procedure specified for the actual machine; do not assume every cleaner has the same mode or preparation time.
How long should a cleaning cycle take?
There is no universal cycle time. Follow the applicable equipment and chemical guidance, then assess the result using a suitable inspection method. Increasing time repeatedly is not a substitute for checking chemistry, loading and material suitability.
Bath maintenance, drainage and aftercare
Plan liquid replacement around contamination and the cleaning result, rather than assuming every bath lasts a fixed number of days. Monitor the process and follow the solution supplier's guidance. Replace contaminated liquid when required and prepare the fresh bath correctly.
The listed cleaners include drainage, which helps emptying. Allow space for controlled draining and follow the instructions for cooling, shutdown and cleaning the tank. Handle and dispose of used liquid according to its composition and collected contamination.
Include rinsing and drying in your workflow where the process requires them. Cleaning residues left on a component can affect the finished result, and some parts need further care before storage or reassembly.
Check these details before ordering
- Component size and weight: give maximum dimensions and intended basket loading.
- Material: identify alloys, finishes and any sensitive assembled parts.
- Contamination: describe oil, grease, deposits or other residues.
- Workload: record batch size and the time available for the complete process.
- Required controls: identify heating, timing, degassing or other functions essential to your method.
- Installation: check electrical configuration, support surface, handling space and drainage arrangements.
Send these details through our Request a Quote page for help comparing the available options. For dry floor cleaning and other tasks, return to our Cleaning Equipment collection.
Ultrasonic cleaners: frequently asked questions
Can I use any solvent in an ultrasonic cleaner?
No. Use only liquids approved for the machine and process. Do not put flammable liquids directly into an ordinary ultrasonic cleaning tank. Follow the equipment instructions and chemical supplier's guidance.
Will an ultrasonic cleaner sterilise components?
Ultrasonic cleaning does not, by itself, establish sterilisation. Where a validated disinfection or sterilisation process is required, select equipment and procedures specifically approved for that purpose.
Should I choose the larger machine?
Choose the machine that accommodates your components and workload with suitable controls. Extra volume can mean more liquid to prepare, heat and replace. Confirm that the additional space provides a practical benefit.
What cannot go in an ultrasonic cleaner?
Exclude items that are incompatible with immersion, ultrasonic action, the chosen chemistry or temperature. Check component documentation rather than relying on a general list, particularly for coated, delicate or assembled items.